Cummins 250kVA Generator-3 Phase 50Hz AC400V
Features
- Cummins Quiet 250kVA Commercial Rental Backup Standby Diesel Generator
- All-Weather Compact Enclosure Design Rated For Indoor and Outdoor Use
- 50Hz 3-Phase AC400V Stable & Continuous Power Output
- 50Hz 3-Phase AC380V, AC415V, AC440V as optional
- Remote Monitor and Control By App or PC As Optional
- User-friendly Digital Control Panel With Multi Data Display
- Generator Multi-Protection (Alarm & Shutdown)
- Integrated Extend 8-12 hrs Fuel Tank Without Frequent Refueling
- Advanced Sound-reduce technology and housing design
Short description
Cummins 250kVA generator is powered by a Cummins 6LTAA8.9-G2 6-cylinder water-cooled diesel engine with an all-weather soundproof enclosure to minimize noise 76db and an integrated fuel tank for extended run times without refueling less than 53 L/h fuel consumption. an AVR for stable power output, also includes safety features, such as automatic shutdown in case of low oil levels or other critical issues.
Feature
Buy From Manufacturer
User Friendly Operation
7/24 hrs Service Online
Power Up Your Business With A Continuous Cummins 250kVA Generator
Commercial/Rental/Small Business etc Application
50HZ 3-Phase AC 380/400/415V Optional
8.9 Litre 6-Cylinder Water Cooled Diesel Engine Generator
Output Voltage Options – 50 Hz 3-Phase
- AC220/380, 3-phase, 0.8 pf , 200 kW/ 250 kVa, 379.8 Amps
- AC230/400, 3-phase, 0.8 pf , 200 kW/ 250 kVa, 360.0 Amps
- AC240/415, 3-phase, 0.8 pf, 200 kW/ 250 kVa, 347.8 Amps
POWER RATINGS:
220.0KW (275KVA) STANDBY, 200.0KW (250KVA) PRIME, 3PHASE, 0.8PF, 50HZ
Benefits of Cummins 250kVA Generator
- Automatic Transfer Switch (ATS) Compatible:
- We install the ATS panel between the city electric meter and the circuit breaker panel. It watches the city's power lines 7/24hrs and the generator automatically starts when it senses a power loss. After starting up, it tells the ATS to disconnect the house from the power grid and use the generator instead. It all happens automatically within seconds after an outage.
- Stable & Continuous Power Output:
- From No-load to a rated load, It maintains voltage varies within ±0.5%, frequency varies within ±2%, Ensures smooth power output, and protects the electrical device.
- AC380V, AC415, AC440 etc Multi Voltage optional
- Remote Monitoring Capability:
- You can keep track of and manage the Cummins 250kVA generator from virtually any location globally. Check the generator's status and control it manually with the Cloud Connect Smartphone App on mobile devices or computers.
- All-Weather Enclosure Design :
- Compact Enclosure Overall Size: 141.7" x 44.4" x 70.8" (L x W x H) inch
- All-weather enclosure design rated for indoor and outdoor use.
- Low Noise Design:
- Advanced sound-reduce technology and housing design with a corrosion-resistant finish reduce noise and vibration. Sound levels less than 76dBA at a 7m distance make the Cummins 250kVA generator among the quietest in their class
- Cummins Reliability:
- The Cummins 250kVA generator is built on a trusted Cummins reputation and guarantees durability and dependable operation.
- Digital Control Panel:
- Data Display: voltage, current, frequency, speed, battery, lube oil pressure, coolant temp, and more, Easy access for users.
- Generator Protection:
- Alarm and Shutdown: Under/Over Voltage, Under/Over Speed, Under/Over Frequency, Low Oil Pressure, High Water Temp
- Extended 8-12hrs Fuel Tank:
- An integrated fuel tank provides 8-12 hours of running without frequent refueling.
Specification of Cummins 250kVA Generator:
- Manufacturer - METCL
- Model - C275GF/S
- Clean Diesel Fuel
- Generator Speed - 1500 RPM
- Displacement - 8.9 Litre
- Fuel Consumption at rated 200kW/250KVA Load- 53 Litre/h
- CUMMINS 6LTAA8.9-G2, 240kW, 1500RPM, Turbocharged
- Electronic Isochronous governor
- Industrial-grade cooling system with fan guards and coolant drain extension with in-line valve
- AC Alternator Manufacture - METCL/STAMFORD/Leroy-Somer/Mecc Alte
- AC Alternator 4 Leads, brushless, 100% Copper Windings
- Full load rated Power - 200kW/250kVA
- Rotor and 2/3 pitch winding suppress triple harmonics and guarantee a superior voltage waveform
- Class H Insulation and Self-ventilated drip-proof design
- Electronic automatic voltage regulation (AVR)
- 50 Hz. 1500RPM 3Phase AC400V
- 3-Phase AC380/415/440V etc Multi-voltage as optional
CONSTRUCTION OF Cummins 250kVA Generator
- SS304 stainless steel anti-theft fasteners used.
- Enclosure & Frame Finish-Anti-corrosion power-coated painting
- Built-in 76.6-gallon (290 Liter) Tank
- Vented/Fuel Fill/Cap
- Fitted with Vibration Mounts on the engine/alternator/radiator
- Dimensions - 3600 x 1130 x 1800 (L x W x H)
- Weight - 2,650 kg
Manufacturer Model | C275GF/S |
Generator Type | Enclosure |
Freq & Volt | 50Hz AC400V |
Standby Power | 275 kVA / 220 kW |
Prime Power | 250 kVA / 200 kW |
Rated Current | 360 Amps |
Operation Mode | Auto & Manual |
Weight | 2650 kgs |
Dimension | 3600*1130*1800mm |
Fuel Consumption at 100% Load | 53 L/h |
Fuel Consumption at 75% Load | 39 L/h |
Fuel Consumption at 50% Load | 27 L/h |
Fuel Consumption at 25% Load | 15 L/h |