Prime Cummins 500kW Generator-3 Phase 50Hz AC400V
Features
- Prime Cummins Quiet 500kW Commercial Rental Backup Diesel Generator
- All-Weather Compact Enclosure Design Rated For Indoor and Outdoor Use
- 50Hz 3-Phase AC400V Stable & Continuous Power Output
- 50Hz 3-Phase AC380V, AC415V, AC440V as optional
- Remote Monitor and Control By App or PC As Optional
- User-friendly Digital Control Panel With Multi Data Display
- Generator Multi-Protection (Alarm & Shutdown)
- Integrated Extend 8-12 hrs Fuel Tank Without Frequent Refueling
- Advanced Sound-reduce technology and housing design
Short description
Prime Cummins 500kW generator is powered by a Cummins KTAA19-G6A 6-cylinder water-cooled 18.9 Litre diesel engine with an all-weather soundproof enclosure to minimize noise 85db and an integrated fuel tank for extended run times without refueling less than 142L/h fuel consumption. an AVR for stable power output, also includes safety features, such as automatic shutdown in case of low oil levels or other critical issues.
Feature
Buy From Manufacturer
User Friendly Operation
7/24 hrs Service Online
Power Up With A Continuous Cummins 500kW Generator
Commercial/Rental/Business/Powerhouse etc Application
50HZ 3-Phase AC 380/400/415V Optional
18.9 Litre 6-cylinder water-cooled Diesel Engine Generator
Output Voltage Options – 50 Hz 3-Phase
- AC220/380, 3-phase, 0.8 pf , 500 kW/ 625 kVa, 949.6 Amps
- AC230/400, 3-phase, 0.8 pf , 500 kW/ 625 kVa, 900.0 Amps
- AC240/415, 3-phase, 0.8 pf, 500 kW/ 625 kVa, 869.5 Amps
POWER RATINGS:
550KW (687.5 KVA) STANDBY, 500KW (625KVA) PRIME, 3PHASE, 0.8PF, 50HZ
Benefits of Prime Cummins 500kW Generator
- Automatic Transfer Switch (ATS) Compatible:
- We install the ATS panel between the city electric meter and the circuit breaker panel. It watches the city's power lines 7/24hrs and the generator automatically starts when it senses a power loss. After starting up, it tells the ATS to disconnect the house from the power grid and use the generator instead. It all happens automatically within seconds after an outage.
- Stable & Continuous Power Output:
- From No-load to a rated load, It maintains voltage varies within ±0.5%, frequency varies within ±2%, Ensures smooth power output, and protects the electrical device.
- AC380V, AC415, AC440 etc Multi Voltage optional
- Remote Monitoring Capability:
- You can keep track of and manage the Prime Cummins 500kW generator from virtually any location globally. Check the generator's status and control it manually with the Cloud Connect Smartphone App on mobile devices or computers.
- All-Weather Enclosure Design :
- Compact Enclosure Overall Size: 204.7" x 70.8" x 94.5" (L x W x H) inch
- All-weather enclosure design rated for indoor and outdoor use.
- Low Noise Design:
- Advanced sound-reduce technology and housing design with a corrosion-resistant finish reduce noise and vibration. Sound levels less than 85dBA at a 7m distance make the prime Cummins 500kW generator among the quietest in their class
- Cummins Reliability:
- The Cummins 500kW generator is built on a trusted Cummins reputation and guarantees durability and dependable operation.
- Digital Control Panel:
- Data Display: voltage, current, frequency, speed, battery, lube oil pressure, coolant temp, and more, Easy access for users.
- Generator Protection:
- Alarm and Shutdown: Under/Over Voltage, Under/Over Speed, Under/Over Frequency, Low Oil Pressure, High Water Temp
- Extended 8-12hrs Fuel Tank:
- An integrated fuel tank provides 8-12 hours of running without frequent refueling.
Specification of Prime Cummins 500kW Generator:
- Manufacturer - METCL
- Model - C688GF/S
- Clean Diesel Fuel
- Generator Speed - 1500 RPM
- Displacement - 18.9 Litre
- Fuel Consumption at rated 500kW/625KVA Load- 142 Litre/h
- CUMMINS KTAA19-G6A, 610kW, 1500RPM, Turbocharged
- Electronic Isochronous governor
- Industrial-grade cooling system with fan guards and coolant drain extension with in-line valve
- AC Alternator Manufacture - METCL/STAMFORD/Leroy-Somer/Mecc Alte
- AC Alternator 4 Leads, brushless, 100% Copper Windings
- Full load rated Power - 500kW/625kVA
- Rotor and 2/3 pitch winding suppress triple harmonics and guarantee a superior voltage waveform
- Class H Insulation and Self-ventilated drip-proof design
- Electronic automatic voltage regulation (AVR)
- 50 Hz. 1500RPM 3Phase AC400V
- 3-Phase AC380/415/440V etc Multi-voltage as optional
CONSTRUCTION OF Cummins 500kW Generator
- SS304 stainless steel anti-theft fasteners used.
- Enclosure & Frame Finish-Anti-corrosion power-coated painting
- Built-in 219.3-gallon (830 Liter) Tank
- Vented/Fuel Fill/Cap
- Fitted with Vibration Mounts on the engine/alternator/radiator
- Dimensions - 5200 x 1800 x 2400 (L x W x H)
- Weight - 6,690 kg
Manufacturer Model | C688GF/S |
Generator Type | Enclosure |
Freq & Volt | 50Hz AC400V |
Standby Power | 687.5 kVA / 550 kW |
Prime Power | 625 kVA / 500 kW |
Rated Current | 900 Amps |
Operation Mode | Auto & Manual |
Weight | 6690 kgs |
Dimension | 5200*1800*2400mm |
Fuel Consumption at 100% Load | 142 L/h |
Fuel Consumption at 75% Load | 99 L/h |
Fuel Consumption at 50% Load | 68 L/h |
Fuel Consumption at 25% Load | 40 L/h |